How to backwash a sand filter with a multiport dial valve:
- 1. Shut off pump motor.
- 2. Press down on dial valve handle on top of the filter and rotate valve from FILTER to BACKWASH position.
- 3. Open the backwash line valve or roll out the backwash hose.
- 4. Turn pump on for three minutes.
- 5. Shut off pump motor and move multiport dial valve handle to RINSE position. Run on rinse for 15-25 seconds.
- 8. Shut off pump motor and move multiport dial valve handle back to FILTER position.
- 9. Turn pump back on and note lower pressure on filter pressure gauge. Close backwash valve or roll up backwash hose.